{"id":10466,"date":"2026-11-11T06:24:00","date_gmt":"2026-11-11T06:24:00","guid":{"rendered":"https:\/\/inskill.in\/training\/?p=10466"},"modified":"2026-11-09T07:28:20","modified_gmt":"2026-11-09T07:28:20","slug":"how-to-debug-scan-chain-failure","status":"publish","type":"post","link":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/","title":{"rendered":"How to Debug a Scan Chain Failure in VLSI: Step-by-Step DFT Debugging with Examples"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"10466\" class=\"elementor elementor-10466\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-453a6c9 elementor-section-boxed elementor-section-height-default elementor-section-height-default wpr-particle-no wpr-jarallax-no wpr-parallax-no wpr-sticky-section-no wpr-column-slider-no wpr-equal-height-no\" data-id=\"453a6c9\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4a4681f\" data-id=\"4a4681f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8bb3b40 elementor-widget elementor-widget-text-editor\" data-id=\"8bb3b40\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">Scan chain testing is a fundamental part of Design for Testability (DFT). It improves the controllability and observability of internal sequential logic by connecting scan flip-flops into shift registers. During test mode, test data is shifted into the scan chain, captured by the circuit, and shifted out for comparison with the expected response.<\/span><\/p><p><span style=\"font-weight: 400;\">However, scan testing can fail at different stages. A scan chain may not shift data correctly, scan output may become stuck, or the chain may pass shift testing but fail during capture. These failures can result from scan-cell connectivity problems, incorrect scan-enable control, clock or reset issues, timing violations, scan-chain reordering mistakes, or test-configuration errors.<\/span><\/p><p><span style=\"font-weight: 400;\">Debugging requires more than checking whether an ATPG pattern passes or fails. Engineers must first identify the failure signature, isolate the affected chain, inspect the scan architecture, and determine whether the problem is structural, timing-related, or pattern-specific.<\/span><\/p><p><span style=\"font-weight: 400;\">This article explains a systematic approach to debugging scan chain failures, including practical examples and the checks commonly performed during DFT implementation and validation.<\/span><\/p><h3><span style=\"font-weight: 400;\">Understanding How a Scan Chain Works<\/span><\/h3><p><span style=\"font-weight: 400;\">A scan chain is formed by connecting the scan input (SI) and scan output (SO) terminals of scan flip-flops in a serial path. A scan flip-flop typically has a functional data input and a scan data input selected through a multiplexer controlled by scan enable.<\/span><\/p><p><span style=\"font-weight: 400;\">When scan enable is asserted, the flip-flop receives data from the previous scan cell. When scan enable is deasserted, it captures functional data.<\/span><\/p><p><span style=\"font-weight: 400;\">For example, consider a scan chain containing four scan flip-flops:<\/span><\/p><p><span style=\"font-weight: 400;\">SI \u2192 FF1 \u2192 FF2 \u2192 FF3 \u2192 FF4 \u2192 SO<\/span><\/p><p><span style=\"font-weight: 400;\">If the input sequence is shifted into the chain, each active scan clock moves the stored data by one position. After the required number of shift cycles, the data can be observed at the scan output.<\/span><\/p><p><span style=\"font-weight: 400;\">A typical scan test involves three operations:<\/span><\/p><ol><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Shift-in:<\/b><span style=\"font-weight: 400;\"> Load the test stimulus into the scan chain.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Capture:<\/b><span style=\"font-weight: 400;\"> Apply the required functional or test clock pulse to capture the circuit response.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Shift-out:<\/b><span style=\"font-weight: 400;\"> Unload the captured response and compare it with the expected data.<\/span><\/li><\/ol><p><span style=\"font-weight: 400;\">A failure during any of these operations can produce a scan test failure. The first debugging task is therefore to identify whether the problem occurs during shift-in, capture, or shift-out.<\/span><\/p><h3><span style=\"font-weight: 400;\">Identify the Type of Scan Chain Failure<\/span><\/h3><p><span style=\"font-weight: 400;\">Before modifying the design or test setup, classify the failure using simulation waveforms, scan reports, ATPG logs, and tester results.<\/span><\/p><p><span style=\"font-weight: 400;\">Common scan chain failure signatures include:<\/span><\/p><table><tbody><tr><td><p><b>Failure type<\/b><\/p><\/td><td><p><b>Typical observation<\/b><\/p><\/td><td><p><b>Possible cause<\/b><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Stuck-at failure<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Scan output remains at 0 or 1<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Stuck signal, faulty cell, reset or control issue<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Open-chain failure<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Data stops propagating beyond a point<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Broken connection or incorrect scan stitching<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Shift mismatch<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Shifted-out data differs from expected data<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">SI\/SO connectivity, scan-enable or clock issue<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Capture failure<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Shift passes but captured response mismatches<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Functional logic, capture clock or timing issue<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Intermittent failure<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Failure changes across runs or frequencies<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Timing, clock integrity or marginal control<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Multiple-chain failure<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Several chains fail together<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Shared scan control, clock, reset or test configuration<\/span><\/p><\/td><\/tr><\/tbody><\/table><p><span style=\"font-weight: 400;\">A constant scan output does not automatically prove that a scan flip-flop is defective. The scan clock may not be reaching the cell, scan enable may be incorrect, or an asynchronous reset may be active. Debugging should follow the signal path before concluding that a particular cell is faulty.<\/span><\/p><h3><span style=\"font-weight: 400;\">Start with a Scan Chain Flush Test<\/span><\/h3><p><span style=\"font-weight: 400;\">A scan chain flush test is one of the most useful first checks. It verifies whether data can propagate through the complete chain without involving complex functional logic.<\/span><\/p><p><span style=\"font-weight: 400;\">The procedure is straightforward:<\/span><\/p><ol><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Enable scan mode.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Apply a known data sequence at scan input.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Apply the required number of shift-clock pulses.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Observe scan output.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Compare the observed sequence with the expected delayed sequence.<\/span><\/li><\/ol><p><span style=\"font-weight: 400;\">For a chain of four flip-flops, suppose the input sequence is <\/span><span style=\"font-weight: 400;\">1, 0, 1, 1<\/span><span style=\"font-weight: 400;\">. After the appropriate number of clock cycles, the same sequence should emerge at scan output in the expected order, subject to the chain&#8217;s defined shifting convention.<\/span><\/p><p><span style=\"font-weight: 400;\">If the chain is functioning correctly, the output should reflect the shifted-in data after the chain latency. If the output remains constant or the sequence becomes corrupted, investigate the chain before debugging ATPG capture patterns.<\/span><\/p><p><b>Practical example:<\/b><\/p><p><span style=\"font-weight: 400;\">Assume a scan chain contains 100 scan cells. During a flush test, the first 40 expected output bits match, but subsequent output bits remain at logic 0.<\/span><\/p><p><span style=\"font-weight: 400;\">This suggests that the failure may be located around the point where data propagation stops. The exact cell location must be determined using the scan-chain order and the direction in which the chain is counted. Check the scan-chain connectivity report and trace the corresponding SI-to-SO path in the netlist.<\/span><\/p><p><span style=\"font-weight: 400;\">Do not assume that the 41st observed bit directly identifies the 41st scan cell. The relationship depends on the chain ordering and observation direction.<\/span><\/p><p><span style=\"font-weight: 400;\">If multiple scan chains are present, run the flush test separately for each chain. This helps isolate whether the failure is limited to one chain or caused by a shared test signal.<\/span><\/p><h3><span style=\"font-weight: 400;\">Check Scan Enable and Scan Control Signals<\/span><\/h3><p><span style=\"font-weight: 400;\">Scan enable controls whether scan flip-flops operate in scan mode or functional mode. Incorrect scan-enable timing can prevent data from shifting correctly.<\/span><\/p><p><span style=\"font-weight: 400;\">Check the following:<\/span><\/p><ul><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Is scan enable asserted before the first shift-clock edge?<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Does scan enable remain stable throughout the shift operation?<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Is it deasserted at the correct point before capture?<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Is the signal connected to all intended scan cells?<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Are there polarity differences between scan cells or test modes?<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Does the testbench or test procedure drive the correct value?<\/span><\/li><\/ul><p><b>Example: Scan enable changes during shifting<\/b><\/p><p><span style=\"font-weight: 400;\">Consider a chain of 500 scan cells. The first 200 bits shift correctly, but later bits do not match the expected response. Waveform inspection shows that scan enable briefly deasserts during the shift sequence.<\/span><\/p><p><span style=\"font-weight: 400;\">When scan enable is low, the scan flip-flops select their functional data inputs instead of their scan inputs. Consequently, the serial scan data path is interrupted.<\/span><\/p><p><span style=\"font-weight: 400;\">The corrective action is to check scan-enable generation, testbench sequencing, and any logic that controls scan mode. Also verify that scan enable reaches the relevant cells after synthesis and scan insertion.<\/span><\/p><h3><span style=\"font-weight: 400;\">Verify Scan Clock Connectivity and Clock Configuration<\/span><\/h3><p><span style=\"font-weight: 400;\">Clock-related issues are another major source of scan chain failures. Scan cells must receive valid shift-clock pulses with the intended polarity and timing.<\/span><\/p><p><span style=\"font-weight: 400;\">Check:<\/span><\/p><ul><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Scan clock source and frequency.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clock mux selection in test mode.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clock-gating bypass or test-enable configuration.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clock polarity and active edge.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clock connectivity to every scan cell.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clock-domain mixing and lock-up latch requirements.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Whether the clock waveform is consistent across simulation and tester procedures.<\/span><\/li><\/ul><p><b>Example: Clock-gated scan cell<\/b><\/p><p><span style=\"font-weight: 400;\">Suppose a design contains two scan chains in different clock-gated blocks. Chain A shifts correctly, while Chain B does not respond to scan-clock pulses.<\/span><\/p><p><span style=\"font-weight: 400;\">Waveform inspection shows that the integrated clock-gating cell for Block B is not enabled in test mode. The scan clock is present at the clock-gating input, but no clock pulses reach the scan cells.<\/span><\/p><p><span style=\"font-weight: 400;\">The investigation should focus on the clock-gating test-enable connection and the intended test-mode clock architecture. Confirm the implementation against the DFT constraints and the clock-gating cell&#8217;s supported test behavior.<\/span><\/p><p><span style=\"font-weight: 400;\">For designs containing multiple clock domains or different clock edges, inspect the scan architecture for appropriate lock-up latch insertion. A missing or incorrectly configured lock-up latch can lead to race or hold-related problems during shifting.<\/span><\/p><h3><span style=\"font-weight: 400;\">Inspect Scan Chain Connectivity and Scan Reordering<\/span><\/h3><p><span style=\"font-weight: 400;\">Scan insertion tools connect scan cells based on the defined DFT architecture. Scan-chain reordering may subsequently change the physical sequence to improve routing.<\/span><\/p><p><span style=\"font-weight: 400;\">A mismatch can occur if the scan-chain description used for pattern generation or simulation does not match the final implemented netlist.<\/span><\/p><p><span style=\"font-weight: 400;\">Important checks include:<\/span><\/p><ul><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Scan-in and scan-out port mapping.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Scan-cell SI and SO connectivity.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Chain length and chain membership.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Scan-chain ordering before and after reordering.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Hierarchical boundary connections.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Bypass and wrapper configuration.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Final netlist consistency with the ATPG setup.<\/span><\/li><\/ul><p><b>Example: Scan reordering mismatch<\/b><\/p><p><span style=\"font-weight: 400;\">Assume a chain initially follows this order:<\/span><\/p><p><span style=\"font-weight: 400;\">SI \u2192 FF1 \u2192 FF2 \u2192 FF3 \u2192 FF4 \u2192 SO<\/span><\/p><p><span style=\"font-weight: 400;\">After physical optimization, the chain is reordered as:<\/span><\/p><p><span style=\"font-weight: 400;\">SI \u2192 FF3 \u2192 FF1 \u2192 FF4 \u2192 FF2 \u2192 SO<\/span><\/p><p><span style=\"font-weight: 400;\">The reordered chain may be valid, but the ATPG patterns and simulation setup must use the updated chain information. If pattern simulation uses the old ordering, the shifted-out data can appear incorrect even though the physical scan path is connected properly.<\/span><\/p><p><span style=\"font-weight: 400;\">Compare the final scan-chain report, chain description, and ATPG configuration. Regenerate or update the relevant test data when the implemented chain order has changed.<\/span><\/p><h3><span style=\"font-weight: 400;\">Check Reset and Set Signals During Scan Operation<\/span><\/h3><p><span style=\"font-weight: 400;\">Asynchronous reset and set pins can override normal scan-cell behavior. If these controls become active during scan shifting, the affected flip-flops may be forced to a constant value.<\/span><\/p><p><span style=\"font-weight: 400;\">For example, suppose a scan chain contains 300 cells and the scan output becomes stuck after a particular section. The corresponding scan cells share an asynchronous reset signal. Waveform inspection shows that reset is briefly asserted during scan shifting.<\/span><\/p><p><span style=\"font-weight: 400;\">The reset event can clear those scan cells, destroying the data being shifted through the chain.<\/span><\/p><p><span style=\"font-weight: 400;\">Debugging steps:<\/span><\/p><ol><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check reset polarity and active level.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Confirm reset is inactive during scan shifting unless the test procedure intentionally requires otherwise.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Inspect reset synchronization and test-mode overrides.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check whether reset is connected to the intended scan cells.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Review DFT design-rule-check reports for reset controllability issues.<\/span><\/li><\/ol><p><span style=\"font-weight: 400;\">Also distinguish between a reset-related shift failure and a capture failure. A reset that is incorrectly released around capture can cause functional response mismatches even when the chain shifts correctly.<\/span><\/p><h3><span style=\"font-weight: 400;\">Distinguish Shift Failures from Capture Failures<\/span><\/h3><p><span style=\"font-weight: 400;\">A scan chain can pass shift testing and still fail during capture. This distinction is important because the debugging direction changes.<\/span><\/p><p><b>Shift failure:<\/b><span style=\"font-weight: 400;\"> The scan data cannot be loaded or unloaded correctly. Investigate scan connectivity, scan enable, clock delivery, reset behavior, and shift timing.<\/span><\/p><p><b>Capture failure:<\/b><span style=\"font-weight: 400;\"> The scan chain shifts correctly, but the captured functional response differs from the expected value. Investigate functional logic, capture-clock sequencing, constraints, timing, unknown values, and test-mode configuration.<\/span><\/p><p><b>Practical example:<\/b><\/p><p><span style=\"font-weight: 400;\">A design contains 2,000 scan cells across several blocks. All chains pass the shift test, but a subset of ATPG patterns fail during capture.<\/span><\/p><p><span style=\"font-weight: 400;\">The first step is to inspect the failing pattern and identify the failing observation point. Then check the relevant capture-clock waveform, launch and capture sequence, clock-domain relationships, and functional logic feeding the observed scan cell.<\/span><\/p><p><span style=\"font-weight: 400;\">For transition-delay testing, confirm that the intended at-speed launch and capture pulses are applied. Also verify the on-chip clock controller (OCC) configuration where applicable.<\/span><\/p><p><span style=\"font-weight: 400;\">Do not attempt to fix a capture mismatch by changing scan-chain connectivity unless the evidence points to a chain-structure problem.<\/span><\/p><h3><span style=\"font-weight: 400;\">Review Scan Timing and Hold Violations<\/span><\/h3><p><span style=\"font-weight: 400;\">Scan shifting can expose timing problems that are not visible in functional operation. In particular, short paths between adjacent scan cells can be vulnerable to hold violations.<\/span><\/p><p><span style=\"font-weight: 400;\">For example, two scan cells may be driven by clocks with different arrival times. If the capture or shift clock relationship is not handled correctly, data may propagate too quickly from one cell to the next, causing a hold violation or race condition.<\/span><\/p><p><span style=\"font-weight: 400;\">Review:<\/span><\/p><ul><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Scan shift setup and hold reports.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clock skew between adjacent scan cells.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clock-domain and edge mixing.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Lock-up latch insertion and placement.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Shift frequency and duty cycle.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Timing constraints for test mode.<\/span><\/li><\/ul><p><span style=\"font-weight: 400;\">A chain that passes at a lower shift frequency but fails at a higher frequency may indicate a timing or clock-integrity issue. However, frequency-dependent behavior should be confirmed with timing analysis and waveform evidence rather than treated as proof of a hold violation.<\/span><\/p><h3><span style=\"font-weight: 400;\">Use ATPG and Simulation Reports to Narrow Down the Failure<\/span><\/h3><p><span style=\"font-weight: 400;\">ATPG reports provide useful information about pattern generation, fault detection, and test coverage. Simulation reports help establish whether the generated patterns produce the expected response in the implemented design model.<\/span><\/p><p><span style=\"font-weight: 400;\">When a scan test fails, review:<\/span><\/p><ul><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Failing pattern number and test mode.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Failing scan chain and scan-out channel.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Expected and observed response.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Failing cycle and bit position.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Fault model and fault category.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Unknown or masked response bits.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Scan-chain configuration used during pattern generation.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Simulation warnings and timing violations.<\/span><\/li><\/ul><p><span style=\"font-weight: 400;\">For compressed scan architectures, also inspect decompressor, compactor, masking logic, and channel mapping. A failure in compression logic or an incorrect configuration can affect several internal chains and may not resemble a simple single-chain break.<\/span><\/p><p><span style=\"font-weight: 400;\">A useful debugging sequence is to reproduce the failing pattern in simulation, inspect the failing cycle, trace the response back through the scan path, and correlate the result with the final scan-chain and timing reports.<\/span><\/p><h3><span style=\"font-weight: 400;\">A Practical Scan Chain Debugging Workflow<\/span><\/h3><p><span style=\"font-weight: 400;\">Use the following sequence to avoid spending time on unrelated parts of the design:<\/span><\/p><ol><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Confirm the failure stage:<\/b><span style=\"font-weight: 400;\"> Determine whether the failure occurs during shift-in, capture, or shift-out.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Identify the affected chain:<\/b><span style=\"font-weight: 400;\"> Separate single-chain failures from failures affecting multiple chains.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Run a flush test:<\/b><span style=\"font-weight: 400;\"> Check basic scan data propagation using a known sequence.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Inspect scan controls:<\/b><span style=\"font-weight: 400;\"> Verify scan enable, test mode, reset, and scan clock.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Trace the chain:<\/b><span style=\"font-weight: 400;\"> Compare scan-cell connectivity and ordering against the final netlist.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Check timing:<\/b><span style=\"font-weight: 400;\"> Review shift-mode setup and hold reports, clock skew, and lock-up latch requirements.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Reproduce the failure:<\/b><span style=\"font-weight: 400;\"> Simulate the failing pattern and inspect the exact mismatch cycle.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Check compression and configuration:<\/b><span style=\"font-weight: 400;\"> For compressed designs, verify decompressor, compactor, masking, and channel mapping.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Apply the correction:<\/b><span style=\"font-weight: 400;\"> Fix the identified design, constraint, or test-configuration issue.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Revalidate:<\/b><span style=\"font-weight: 400;\"> Repeat chain integrity checks and run the relevant ATPG simulation and regression tests.<\/span><\/li><\/ol><p><span style=\"font-weight: 400;\">Keep a record of the failing chain, pattern, cycle, expected value, observed value, suspected cause, and corrective action. This makes the debugging process easier to review and helps prevent the same issue from recurring.<\/span><\/p><h3><span style=\"font-weight: 400;\">Common Mistakes to Avoid During Scan Debugging<\/span><\/h3><p><span style=\"font-weight: 400;\">Some debugging approaches create additional confusion instead of identifying the root cause.<\/span><\/p><ul><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Starting with ATPG pattern changes:<\/b><span style=\"font-weight: 400;\"> First confirm that the scan chain itself shifts correctly.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Assuming every constant output is a defective flip-flop:<\/b><span style=\"font-weight: 400;\"> Check clocks, resets, scan enable, and connectivity.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ignoring the final netlist:<\/b><span style=\"font-weight: 400;\"> Scan reordering and implementation changes can make earlier chain descriptions outdated.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Overlooking test-mode clock gating:<\/b><span style=\"font-weight: 400;\"> A clock that works in functional mode may not reach scan cells in test mode.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Treating shift and capture failures as identical:<\/b><span style=\"font-weight: 400;\"> They involve different signal paths and debugging checks.<\/span><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><b>Ignoring compression logic:<\/b><span style=\"font-weight: 400;\"> In compressed scan designs, internal chain failures may be related to decompression or compaction configuration.<\/span><\/li><\/ul><h4><span style=\"font-weight: 400;\">Conclusion<\/span><\/h4><p><span style=\"font-weight: 400;\">Debugging a scan chain failure requires a structured approach that begins with identifying the failure stage and verifying basic scan data propagation. A flush test helps establish chain integrity. Scan enable, clock, reset, connectivity, reordering, and timing checks then help isolate structural and shift-related problems. If shifting passes but ATPG patterns fail during capture, the investigation should move toward functional logic, capture-clock sequencing, timing constraints, and response masking.<\/span><\/p><p><span style=\"font-weight: 400;\">For DFT engineers, the ability to interpret scan-chain reports, reproduce failures in simulation, and correlate ATPG results with the implemented netlist is essential. Practical experience with scan insertion, ATPG debugging, test compression, and DFT diagnosis helps develop this systematic problem-solving approach.<\/span><\/p><p><span style=\"font-weight: 400;\">Engineers who want to build these skills can explore <\/span><a href=\"https:\/\/inskill.in\/training\/dft-training\/\"><span style=\"font-weight: 400;\">DFT Training at InSkill<\/span><\/a><span style=\"font-weight: 400;\">, which covers scan insertion, scan-chain validation, ATPG simulation debug, and diagnosis. For additional exposure to scan and ATPG implementation workflows, see <\/span><a href=\"https:\/\/vlsiguru.com\/freshers\/dft-training\"><span style=\"font-weight: 400;\">DFT Training at VLSIGuru<\/span><\/a><span style=\"font-weight: 400;\"> and <\/span><a href=\"https:\/\/vlsiguru.com\/working-professionals\/advanced-dft-training\"><span style=\"font-weight: 400;\">Advanced DFT Training at VLSIGuru<\/span><\/a><span style=\"font-weight: 400;\">.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Scan chain testing is a fundamental part of Design for Testability (DFT). It improves the controllability and observability of internal sequential logic by connecting scan flip-flops into shift registers. During test mode, test data is shifted into the scan chain, captured by the circuit, and shifted out for comparison with the expected response. However, scan testing can fail at different stages. A scan chain may not shift data correctly, scan output may become stuck, or the chain may pass shift testing but fail during capture. These failures can result from scan-cell connectivity problems, incorrect scan-enable control, clock or reset issues, timing violations, scan-chain reordering mistakes, or test-configuration errors. Debugging requires more than checking whether an ATPG pattern passes or fails. Engineers must first identify the failure signature, isolate the affected chain, inspect the scan architecture, and determine whether the problem is structural, timing-related, or pattern-specific. This article explains a systematic approach to debugging scan chain failures, including practical examples and the checks commonly performed during DFT implementation and validation. Understanding How a Scan Chain Works A scan chain is formed by connecting the scan input (SI) and scan output (SO) terminals of scan flip-flops in a serial path. A scan flip-flop typically has a functional data input and a scan data input selected through a multiplexer controlled by scan enable. When scan enable is asserted, the flip-flop receives data from the previous scan cell. When scan enable is deasserted, it captures functional data. For example, consider a scan chain containing four scan flip-flops: SI \u2192 FF1 \u2192 FF2 \u2192 FF3 \u2192 FF4 \u2192 SO If the input sequence is shifted into the chain, each active scan clock moves the stored data by one position. After the required number of shift cycles, the data can be observed at the scan output. A typical scan test involves three operations: Shift-in: Load the test stimulus into the scan chain. Capture: Apply the required functional or test clock pulse to capture the circuit response. Shift-out: Unload the captured response and compare it with the expected data. A failure during any of these operations can produce a scan test failure. The first debugging task is therefore to identify whether the problem occurs during shift-in, capture, or shift-out. Identify the Type of Scan Chain Failure Before modifying the design or test setup, classify the failure using simulation waveforms, scan reports, ATPG logs, and tester results. Common scan chain failure signatures include: Failure type Typical observation Possible cause Stuck-at failure Scan output remains at 0 or 1 Stuck signal, faulty cell, reset or control issue Open-chain failure Data stops propagating beyond a point Broken connection or incorrect scan stitching Shift mismatch Shifted-out data differs from expected data SI\/SO connectivity, scan-enable or clock issue Capture failure Shift passes but captured response mismatches Functional logic, capture clock or timing issue Intermittent failure Failure changes across runs or frequencies Timing, clock integrity or marginal control Multiple-chain failure Several chains fail together Shared scan control, clock, reset or test configuration A constant scan output does not automatically prove that a scan flip-flop is defective. The scan clock may not be reaching the cell, scan enable may be incorrect, or an asynchronous reset may be active. Debugging should follow the signal path before concluding that a particular cell is faulty. Start with a Scan Chain Flush Test A scan chain flush test is one of the most useful first checks. It verifies whether data can propagate through the complete chain without involving complex functional logic. The procedure is straightforward: Enable scan mode. Apply a known data sequence at scan input. Apply the required number of shift-clock pulses. Observe scan output. Compare the observed sequence with the expected delayed sequence. For a chain of four flip-flops, suppose the input sequence is 1, 0, 1, 1. After the appropriate number of clock cycles, the same sequence should emerge at scan output in the expected order, subject to the chain&#8217;s defined shifting convention. If the chain is functioning correctly, the output should reflect the shifted-in data after the chain latency. If the output remains constant or the sequence becomes corrupted, investigate the chain before debugging ATPG capture patterns. Practical example: Assume a scan chain contains 100 scan cells. During a flush test, the first 40 expected output bits match, but subsequent output bits remain at logic 0. This suggests that the failure may be located around the point where data propagation stops. The exact cell location must be determined using the scan-chain order and the direction in which the chain is counted. Check the scan-chain connectivity report and trace the corresponding SI-to-SO path in the netlist. Do not assume that the 41st observed bit directly identifies the 41st scan cell. The relationship depends on the chain ordering and observation direction. If multiple scan chains are present, run the flush test separately for each chain. This helps isolate whether the failure is limited to one chain or caused by a shared test signal. Check Scan Enable and Scan Control Signals Scan enable controls whether scan flip-flops operate in scan mode or functional mode. Incorrect scan-enable timing can prevent data from shifting correctly. Check the following: Is scan enable asserted before the first shift-clock edge? Does scan enable remain stable throughout the shift operation? Is it deasserted at the correct point before capture? Is the signal connected to all intended scan cells? Are there polarity differences between scan cells or test modes? Does the testbench or test procedure drive the correct value? Example: Scan enable changes during shifting Consider a chain of 500 scan cells. The first 200 bits shift correctly, but later bits do not match the expected response. Waveform inspection shows that scan enable briefly deasserts during the shift sequence. When scan enable is low, the scan flip-flops select their functional data inputs instead of their scan inputs. Consequently, the serial scan data path is interrupted. The corrective action is to check scan-enable generation, testbench sequencing, and any logic that controls scan mode. Also<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[8],"tags":[],"class_list":["post-10466","post","type-post","status-publish","format-standard","hentry","category-vlsi"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Debug a Scan Chain Failure in VLSI: DFT Guide<\/title>\n<meta name=\"description\" content=\"Learn how to debug scan chain failures in VLSI with practical examples covering scan shift, capture, clock, reset, connectivity, timing and ATPG issues.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Debug a Scan Chain Failure in VLSI: DFT Guide\" \/>\n<meta property=\"og:description\" content=\"Learn how to debug scan chain failures in VLSI with practical examples covering scan shift, capture, clock, reset, connectivity, timing and ATPG issues.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/\" \/>\n<meta property=\"og:site_name\" content=\"Inskill VLSIGURU Elearning Platform\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-11T06:24:00+00:00\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"12 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#\\\/schema\\\/person\\\/9abb65edd31606e6675ad9c153f2d42f\"},\"headline\":\"How to Debug a Scan Chain Failure in VLSI: Step-by-Step DFT Debugging with Examples\",\"datePublished\":\"2026-11-11T06:24:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/\"},\"wordCount\":2509,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#organization\"},\"articleSection\":[\"VLSI\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/\",\"url\":\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/\",\"name\":\"How to Debug a Scan Chain Failure in VLSI: DFT Guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#website\"},\"datePublished\":\"2026-11-11T06:24:00+00:00\",\"description\":\"Learn how to debug scan chain failures in VLSI with practical examples covering scan shift, capture, clock, reset, connectivity, timing and ATPG issues.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/vlsi\\\/how-to-debug-scan-chain-failure\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/inskill.in\\\/training\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Debug a Scan Chain Failure in VLSI: Step-by-Step DFT Debugging with Examples\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#website\",\"url\":\"https:\\\/\\\/inskill.in\\\/training\\\/\",\"name\":\"Inskill VLSIGURU Elearning Platform\",\"description\":\"Best VLSI Training Institute\",\"publisher\":{\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/inskill.in\\\/training\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#organization\",\"name\":\"Inskill VLSIGURU Elearning Platform\",\"url\":\"https:\\\/\\\/inskill.in\\\/training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/inskill.in\\\/training\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/inskill-2.png\",\"contentUrl\":\"https:\\\/\\\/inskill.in\\\/training\\\/wp-content\\\/uploads\\\/2025\\\/01\\\/inskill-2.png\",\"width\":207,\"height\":89,\"caption\":\"Inskill VLSIGURU Elearning Platform\"},\"image\":{\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/inskill.in\\\/training\\\/#\\\/schema\\\/person\\\/9abb65edd31606e6675ad9c153f2d42f\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ae1b84b5e32e75453917297a43292af55fcc34a59a0d20dc5403287472a37c28?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ae1b84b5e32e75453917297a43292af55fcc34a59a0d20dc5403287472a37c28?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ae1b84b5e32e75453917297a43292af55fcc34a59a0d20dc5403287472a37c28?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"https:\\\/\\\/inskill.in\\\/training\"],\"url\":\"https:\\\/\\\/inskill.in\\\/training\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Debug a Scan Chain Failure in VLSI: DFT Guide","description":"Learn how to debug scan chain failures in VLSI with practical examples covering scan shift, capture, clock, reset, connectivity, timing and ATPG issues.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/","og_locale":"en_US","og_type":"article","og_title":"How to Debug a Scan Chain Failure in VLSI: DFT Guide","og_description":"Learn how to debug scan chain failures in VLSI with practical examples covering scan shift, capture, clock, reset, connectivity, timing and ATPG issues.","og_url":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/","og_site_name":"Inskill VLSIGURU Elearning Platform","article_published_time":"2026-11-11T06:24:00+00:00","author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"12 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/#article","isPartOf":{"@id":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/"},"author":{"name":"admin","@id":"https:\/\/inskill.in\/training\/#\/schema\/person\/9abb65edd31606e6675ad9c153f2d42f"},"headline":"How to Debug a Scan Chain Failure in VLSI: Step-by-Step DFT Debugging with Examples","datePublished":"2026-11-11T06:24:00+00:00","mainEntityOfPage":{"@id":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/"},"wordCount":2509,"commentCount":0,"publisher":{"@id":"https:\/\/inskill.in\/training\/#organization"},"articleSection":["VLSI"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/","url":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/","name":"How to Debug a Scan Chain Failure in VLSI: DFT Guide","isPartOf":{"@id":"https:\/\/inskill.in\/training\/#website"},"datePublished":"2026-11-11T06:24:00+00:00","description":"Learn how to debug scan chain failures in VLSI with practical examples covering scan shift, capture, clock, reset, connectivity, timing and ATPG issues.","breadcrumb":{"@id":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/inskill.in\/training\/vlsi\/how-to-debug-scan-chain-failure\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/inskill.in\/training\/"},{"@type":"ListItem","position":2,"name":"How to Debug a Scan Chain Failure in VLSI: Step-by-Step DFT Debugging with Examples"}]},{"@type":"WebSite","@id":"https:\/\/inskill.in\/training\/#website","url":"https:\/\/inskill.in\/training\/","name":"Inskill VLSIGURU Elearning Platform","description":"Best VLSI Training Institute","publisher":{"@id":"https:\/\/inskill.in\/training\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/inskill.in\/training\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/inskill.in\/training\/#organization","name":"Inskill VLSIGURU Elearning Platform","url":"https:\/\/inskill.in\/training\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/inskill.in\/training\/#\/schema\/logo\/image\/","url":"https:\/\/inskill.in\/training\/wp-content\/uploads\/2025\/01\/inskill-2.png","contentUrl":"https:\/\/inskill.in\/training\/wp-content\/uploads\/2025\/01\/inskill-2.png","width":207,"height":89,"caption":"Inskill VLSIGURU Elearning Platform"},"image":{"@id":"https:\/\/inskill.in\/training\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/inskill.in\/training\/#\/schema\/person\/9abb65edd31606e6675ad9c153f2d42f","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ae1b84b5e32e75453917297a43292af55fcc34a59a0d20dc5403287472a37c28?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ae1b84b5e32e75453917297a43292af55fcc34a59a0d20dc5403287472a37c28?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ae1b84b5e32e75453917297a43292af55fcc34a59a0d20dc5403287472a37c28?s=96&d=mm&r=g","caption":"admin"},"sameAs":["https:\/\/inskill.in\/training"],"url":"https:\/\/inskill.in\/training\/author\/admin\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/posts\/10466","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/comments?post=10466"}],"version-history":[{"count":8,"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/posts\/10466\/revisions"}],"predecessor-version":[{"id":10479,"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/posts\/10466\/revisions\/10479"}],"wp:attachment":[{"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/media?parent=10466"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/categories?post=10466"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/inskill.in\/training\/wp-json\/wp\/v2\/tags?post=10466"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}